one. Open the door with a password to open the door:
The first step: Press the "1" key 2S until you hear the long "click" sound, indicating that the keyboard has been activated.
Step 2: Enter the remaining 10 digits of the password for unpacking (cabinet) continuously. If the input is correct, turn the handle to open the door.
Note: If there are four short “beep†sounds and the red light flashes twice, you will have to re-enter the unpacking (cabinet) password. If you enter the wrong unpacking (cabinet) password five times in succession, the buzzer will alarm for 30 seconds and the password will open the door. The function is disabled for 5 minutes.
two. Module initialization:
First of all, open the safe, disconnect the power, then press the "0" key to discharge, then hold down the initialization switch and turn on the power supply for 6 seconds and then hear a long "bang" two, while the green light is on two. Then "click" and the green light is on and the initialization is successful.
three. Registering a super fingerprint:
The first step: must first initialize the module, after the initialization is successful, hold down the initialization switch for 3 seconds, hear a long "click" sound, the green light is always on, release the initialization switch;
Step 2: Press the “0†button to power up, the fingerprint window will flash, and the buzzer will respond “short†at the same time. Within 5 seconds, place the finger that will register the super fingerprint on the fingerprint window. The green light will flash and it will be long. "Bang" sounded, indicating that the first time the input was successful, otherwise it was short "beep" twice, and the red light flashed twice to indicate failure;
The third step: Then wait for 1 second, the fingerprint window light flashes again, at the same time, the buzzer responds synchronously with a short “buzzâ€, and the same fingerprint is entered for the second time in 5 seconds. If the length is “doubleâ€, the green light When it goes out, it means the registration is successful; otherwise, if it is short, “beep†four times and the red light flashes four times to indicate failure, the above operation must be repeated;
Note: After successfully registering the super fingerprint, the factory door opening password will automatically be invalid; super fingerprint and ordinary fingerprint cannot be set with the same finger, so as to avoid unnecessary disorder.
four. Register ordinary fingerprints:
The fingerprint fingerprint module of the safe can store up to 4 groups of 16 fingerprints in total.
The first group of one: Super fingerprint (the first fingerprint registered successfully); The maximum authority, out of the box, and can be used to set and delete the other three sets of fingerprint and out of the box password;
The second group of 5: master fingerprint;
The third group of 5: the owner's first backup fingerprint;
The fourth group of 5: the owner of the second backup fingerprint;
Register the master fingerprint step:
The first step: press the "0" key to power on, after using the super fingerprint to open the door, the green light will be on for 5 seconds, hold down the "1" key until the green light goes out, and after about 3 seconds, you hear a long "click" sound. The green light is on for 10 seconds, indicating that it is in the setup state.
Step 2: Press "0" "1" key within 10 seconds, long "click", enter the registered owner's fingerprint status;
Step 3: The fingerprint window flashes, and the buzzer responds synchronously with a short “buzzâ€. Within 5 seconds, the finger used to register the fingerprint is placed on the fingerprint window. If the green light flashes, a long “click†sound indicates the first Subsequent to the success of the input, otherwise short "squeak" four sounds, the red light flashed four times that failed.
Step 4: Then wait for 1 second, the fingerprint window light flashes again, and the buzzer responds synchronously with a short “buzzâ€. The same fingerprint is entered for the second time in 5 seconds. If the length is “tweeted†twice, the green light will turn green. When it goes out, it means that the registration is successful; otherwise, it will be short “beep†four times, and the red light will flash four times to indicate failure. If you want to register the owner’s fingerprint, you must repeat the above operation;
Note: Set the fingerprint in three groups according to the corresponding key combination. If the fingerprint of the group has been registered, the traffic light will flash 8 times alternately. If you want to select another group to register, you must open the door with a super fingerprint and repeat the above operation.
(1) Press "01" to set the master fingerprint;
(2) Press "02" to set the owner's first backup fingerprint;
(3) Press "03" to set the owner's second backup fingerprint;
(4) Press “00†to set the door opening password; enter the same door opening password twice in the setting state; in the state of password input, the green light is on; if the setting is not completed, the green light goes off, the user input is timeout, the input is two. The maximum time interval between digits cannot exceed 10 seconds. After the first password is entered, the password is long and then the same password is entered again within 10 seconds. If there are two long “buzzes†and the green light goes out, the registration is successful. ; Otherwise, short "click" four times, the red light flashes four times to indicate failure, the module gives up this operation, after the success of the set up, the new password will directly overwrite the old password, can only set a user out of the box password.
Note: Only one fingerprint can be registered at a time. The whole group can be deleted. Up to 5 fingerprints can be stored in each group.
Fives. Fingerprint open safe cabinet door operation steps;
The first step: press the power button “0†to power on, the safe module (cabinet) fingerprint module will “click†and the green light will turn on once, and the red light of the fingerprint window will begin to flash;
The second step: When the red light is flashing, press your finger on the fingerprint window. The green light is on and a long “click†indicates that the safe has been unlocked. If there are four short “beep†sounds and the red light flashes four times, it indicates that the fingerprint reads incorrectly or no fingerprint is found. At this time, the fingerprint window light continues to flash, and the user can continue to login another fingerprint to open the door and press each time. With the button, the user has three chances to log in to open the door.
Note: The buzzer alarms for about 30 seconds if the fingerprint is not passed ten consecutive times. After the buzzer alarm (30 seconds) can be used to open the door with a fingerprint or password, fingerprint/password open the door or after 5 minutes, the alarm state is automatically lifted.
Step 3: Turn the knob or knob after successful fingerprint comparison to open the door.
six. Delete fingerprints:
According to the need of use, the registered fingerprint can be deleted (Note: Only the super fingerprint can delete other fingerprints. The deletion of the super fingerprint needs to be completed through module initialization). The method of deleting fingerprints is as follows: Step 1: Press “ 0†button power on, super fingerprint open the door, in the open state, press “3†key to enter the delete state after 5S, hear a long “bang†sound, the green light is on for 10 seconds;
The second step: within 10 seconds
1) Press "01" to delete the master fingerprint;
2) Press "02" to delete the owner's first backup fingerprint;
3) Press "03" to delete the owner's second backup fingerprint;
4) Press “00†to delete the password. The password can be used to directly overwrite the old password when registering the password. It can also be deleted. The deletion is successful. The “green†light is turned on twice. The fingerprint in the group is deleted all at once. . If the deletion is unsuccessful, the red light will be on four times, and the sound will be “beep†four times. Repeat the above operation.