Determination Vertical flame retardant tester Practice a method, flame retardant vertical method tester main purpose <br> <br> fire resistant properties mainly for clothing, fire-retardant fabrics, safety nets, safety belts and the like, and The verification of Lao An and the approval of industrial production licenses have resulted in a high degree of equipment automation and easy operation and safety. The vertical flame tester includes the vertical flame tester, vertical burner, and vertical flame retardant tester.
Second, the main features of the instrument 1, the electric wire automatic ignition 2, burner automatic timing, positioning 3, ignition time 0 to 99.99 seconds arbitrarily set, continue burning time, smoldering time are automatically recorded, digital display 4, flame height adjustable 5, "push-pull" sample holder fixture 6, equipped with combustible gas leakage alarm device
Third, the main technical indicators 1, the inner diameter of the TedeTal type burner: 11mm; tilt angle:>50
2, the burner motor power consumption: 6W
3ã€Ignition timing: 0~99.99 seconds set arbitrarily, international use 12 seconds 4, continued burning time and smoldering time timer: 0~99.99 seconds, precision:±0.01 seconds 5. Flame height measuring device: ruler height 40mm
6, the use of gas: propane, butane, liquefied petroleum gas 7, textile sample size: 80mm × 300mm
8, the working power: AC220v; 50Hz; 50W
9, combustion chamber size: 329 × 329 × 767 (mm) 3
10, weight: about 20K
Fourth, the applicable national standards <br> <br>: GB / T5455-1997 "Textiles - burning behavior - Vertical Method", GB8965.1-2009 "protective clothing flame retardant protective clothing Part 1", GB / T6096-2009 "Safety belt test method", GB5725-2009 "safety net"
V. Random attachments 1. Measure damage length weight 1 set (5)
2. Sample clamp 1 piece 3, burner flame nozzle 1 piece 4, power cord 1
Six, pre-test preparation 1, ready for test specimens.
2, ready for test gas source.
3. Connect the air source to the instrument to ensure that there is no air leakage from the joint.
4. Connect the laboratory power supply and the instrument with the supplied power cord.
5. Place the textile sample in the sample holder and the lower edge of the sample should be flush with the lower end of the sample holder.
VII. Operation Step 1. Open the gas source valve.
2. Close the front door of the combustion chamber and turn on the instrument (power switch "1" side), the power indicator light.
3. Press the “Reset†button to return the burner to the ignition position (if no response, the burner is already in the ignition position, please proceed to the next step).
4. Press and hold the “Ignition†button to light the burner (Note: Keep the “Ignition†button pressed during ignition). After ignition, release the "Ignition" button. If it is difficult to ignite, adjust the "Flame adjustment" button (reducing the combustible gas flow clockwise and increasing the combustible gas flow counterclockwise). Pay attention to adjust the air flow while holding down the "Ignition" button.
5. Open the front door of the combustion test box, place the flame height ruler (height 40mm) in front of the flame by hand, adjust the "flame adjustment" knob, and adjust the flame height to 40mm ± 2mm. After the flame is stabilized, remove the flame height ruler. Hang the specimen vertically with the specimen holder in the center of the box and close the door.
6. Click the "Start" button, the burner is moved to the sample suspension position (this time should be within 1 minute from the time the sample is taken out of the sealed container), and after 12 seconds (or 10 seconds), the burner is stopped. Gas and return to the "continuation time" automatically timed.
7. Observe the condition of the sample in the test chamber. At the same time when the continuous combustion is over, click on the “Continuous stop†button. If there is no continuous combustion, press the button “Continue stop†directly to automatically time the “smear timeâ€. When the smoldering is over, press the “Smoke Stop†button once, then record the continued burning time and the smoldering time, and record the phenomenon that appears during the test.
8. Open the front door of the combustion chamber to remove the specimen holder, remove the specimen, and then use the specified weight according to the weight of the fabric per unit area to determine the length of the damage (see the standard).
9. Press the “CLEAR†button, the instrument will return to the initial state, open the test chamber door, remove the debris from the cabinet, open the ventilation equipment, exhaust the fumes and gases from the test chamber, and wait for the row to finish. Close the row. Wind equipment, this test ended.
10. To continue the test, repeat steps 3-9. If it is not needed, turn off the power (push "power switch" position "0"), then unplug the power cable, close the valve, and the test is completed.
VIII. Precautions 1. Fireworks should be strictly prohibited in the storage of instruments and gas cylinders, and fire should be eliminated. Samples that are still in smoldering after the test must be extinguished in time. Carbon dioxide and other fire fighting equipment should be installed.
2. The gas pipeline must be inspected carefully before starting the machine. Gas leakage is strictly prohibited.
3, the operator should wear protective clothing, protective gloves, so as not to be hand stabbed or burned.
4. This test is best conducted in a fume hood to prepare for immediate removal of harmful gases and replacement of fresh air.
5. After the test is completed, the gas source should be turned off. After the gas in the tube is burned out, turn off the power.
6, the instrument is equipped with gas alarm device, such as the gas alarm ring, please check whether there is leakage.
7. Immediately after the alarm of the gas alarm, turn off the power supply and air supply, and restart the machine after troubleshooting.
8, the instrument must have a good grounding!
This article is the original article of Qingdao Zhongbang Instrument Co., Ltd. If you need to reprint it, be sure to add the source of the description. Reproduce the misappropriation without permission.
Second, the main features of the instrument 1, the electric wire automatic ignition 2, burner automatic timing, positioning 3, ignition time 0 to 99.99 seconds arbitrarily set, continue burning time, smoldering time are automatically recorded, digital display 4, flame height adjustable 5, "push-pull" sample holder fixture 6, equipped with combustible gas leakage alarm device
Third, the main technical indicators 1, the inner diameter of the TedeTal type burner: 11mm; tilt angle:>50
2, the burner motor power consumption: 6W
3ã€Ignition timing: 0~99.99 seconds set arbitrarily, international use 12 seconds 4, continued burning time and smoldering time timer: 0~99.99 seconds, precision:±0.01 seconds 5. Flame height measuring device: ruler height 40mm
6, the use of gas: propane, butane, liquefied petroleum gas 7, textile sample size: 80mm × 300mm
8, the working power: AC220v; 50Hz; 50W
9, combustion chamber size: 329 × 329 × 767 (mm) 3
10, weight: about 20K
Fourth, the applicable national standards <br> <br>: GB / T5455-1997 "Textiles - burning behavior - Vertical Method", GB8965.1-2009 "protective clothing flame retardant protective clothing Part 1", GB / T6096-2009 "Safety belt test method", GB5725-2009 "safety net"
V. Random attachments 1. Measure damage length weight 1 set (5)
2. Sample clamp 1 piece 3, burner flame nozzle 1 piece 4, power cord 1
Six, pre-test preparation 1, ready for test specimens.
2, ready for test gas source.
3. Connect the air source to the instrument to ensure that there is no air leakage from the joint.
4. Connect the laboratory power supply and the instrument with the supplied power cord.
5. Place the textile sample in the sample holder and the lower edge of the sample should be flush with the lower end of the sample holder.
VII. Operation Step 1. Open the gas source valve.
2. Close the front door of the combustion chamber and turn on the instrument (power switch "1" side), the power indicator light.
3. Press the “Reset†button to return the burner to the ignition position (if no response, the burner is already in the ignition position, please proceed to the next step).
4. Press and hold the “Ignition†button to light the burner (Note: Keep the “Ignition†button pressed during ignition). After ignition, release the "Ignition" button. If it is difficult to ignite, adjust the "Flame adjustment" button (reducing the combustible gas flow clockwise and increasing the combustible gas flow counterclockwise). Pay attention to adjust the air flow while holding down the "Ignition" button.
5. Open the front door of the combustion test box, place the flame height ruler (height 40mm) in front of the flame by hand, adjust the "flame adjustment" knob, and adjust the flame height to 40mm ± 2mm. After the flame is stabilized, remove the flame height ruler. Hang the specimen vertically with the specimen holder in the center of the box and close the door.
6. Click the "Start" button, the burner is moved to the sample suspension position (this time should be within 1 minute from the time the sample is taken out of the sealed container), and after 12 seconds (or 10 seconds), the burner is stopped. Gas and return to the "continuation time" automatically timed.
7. Observe the condition of the sample in the test chamber. At the same time when the continuous combustion is over, click on the “Continuous stop†button. If there is no continuous combustion, press the button “Continue stop†directly to automatically time the “smear timeâ€. When the smoldering is over, press the “Smoke Stop†button once, then record the continued burning time and the smoldering time, and record the phenomenon that appears during the test.
8. Open the front door of the combustion chamber to remove the specimen holder, remove the specimen, and then use the specified weight according to the weight of the fabric per unit area to determine the length of the damage (see the standard).
9. Press the “CLEAR†button, the instrument will return to the initial state, open the test chamber door, remove the debris from the cabinet, open the ventilation equipment, exhaust the fumes and gases from the test chamber, and wait for the row to finish. Close the row. Wind equipment, this test ended.
10. To continue the test, repeat steps 3-9. If it is not needed, turn off the power (push "power switch" position "0"), then unplug the power cable, close the valve, and the test is completed.
VIII. Precautions 1. Fireworks should be strictly prohibited in the storage of instruments and gas cylinders, and fire should be eliminated. Samples that are still in smoldering after the test must be extinguished in time. Carbon dioxide and other fire fighting equipment should be installed.
2. The gas pipeline must be inspected carefully before starting the machine. Gas leakage is strictly prohibited.
3, the operator should wear protective clothing, protective gloves, so as not to be hand stabbed or burned.
4. This test is best conducted in a fume hood to prepare for immediate removal of harmful gases and replacement of fresh air.
5. After the test is completed, the gas source should be turned off. After the gas in the tube is burned out, turn off the power.
6, the instrument is equipped with gas alarm device, such as the gas alarm ring, please check whether there is leakage.
7. Immediately after the alarm of the gas alarm, turn off the power supply and air supply, and restart the machine after troubleshooting.
8, the instrument must have a good grounding!
This article is the original article of Qingdao Zhongbang Instrument Co., Ltd. If you need to reprint it, be sure to add the source of the description. Reproduce the misappropriation without permission.
Wireless level sensor is a high-precision, low-power wireless liquid level detection instrument, which consists of input liquid level sensor, signal processing circuit, communication module and power module. It uses a high-capacity, high-energy lithium battery, radio frequency radio transmission data. Installation is simple, easy to use, no need site wiring, leaves out the conventional instrument wiring bypass trouble, save manpower and construction cost, especially suitable for unwired and unpowered application site.
Wireless Level Sensor,Wireless Water Level Indicator,Wireless Water Level Sensor,Wireless Fuel Level Sensor; wireless level transmitter
Xi'an Gavin Electronic Technology Co., Ltd , https://www.gamicos-meas.com