Instrumentation, no matter how good its quality, is inseparable from continuous maintenance and maintenance. Only in this way can it be more precise in operation and maximize the service life. Today, Yijia Instrument will share with you the daily maintenance and maintenance experience of electromagnetic flowmeter. Instrumentation, no matter how good its quality, is inseparable from continuous maintenance and maintenance. Only in this way can it be more precise in operation and maximize the service life. Today, Yijia Instrument will share with you the daily maintenance and maintenance experience of electromagnetic flowmeter. The use of electromagnetic flowmeters is very extensive, saying that it is the innocent king of the flowmeter field, and it is not an exaggeration. Of course, the medium that cannot measure the dielectric constant is too short, which is also determined by the principle of its working measurement and cannot be exceeded. First of all, the most intuitive to check the external situation, such as whether the grounding system is in good contact, whether the sealing part is complete, whether there is dripping or vibration in the pipe installation part, whether the connecting bolt and the mounting bracket are loose. Second, the maintenance and maintenance of the electrode part. There are a lot of references on the Internet for you to check, but this article will be talked about once again and make some additional explanations. 1. Calibration of the electromagnetic flowmeter and cleaning of the electrode. The calibration must use the standard PH value liquid. After the calibration is completed, the electrode should be cleaned with distilled water. After the first cleaning, the electrode to be tested must be cleaned again. Many people tend to ignore this step, in fact, this is also very important. 2. When cleaning or disassembling the electromagnetic flowmeter, it is necessary to protect the electrode part. Collision and damage will affect other uses. 3, electromagnetic flowmeter also need to protect the electrode when not in use, install the electrode sleeve, and keep the bulb moist, here must use a saturated solution, remember not to be placed in distilled water for soaking. 4. In order to maintain the measurement accuracy of the electromagnetic flowmeter, the electrode is the key. Keeping the electrode clean is an important condition to extend its life and maintain measurement accuracy. Finally, the converter part, this is also the key to the electromagnetic flowmeter, but for technical reasons, this part of the fault is generally unable to be used by the unit, so as long as the converter is faulty, it is repaired by the manufacturer. of. For more information on instrumentation, please pay attention to our news section. We will continue to update the content of the website. We will share more experience and share with you. We also hope that you can use some of your own experience. We share, our progress, can not be separated from your comments and suggestions, thank you. This article is from: Electromagnetic flowmeter WWW.CHINA-YJYB.COM Magnetic flap level gauge WWW.YJYWJ.COM http://news.chinawj.com.cn Edit: (Hardware Business Network Information Center) http://news. Chinawj.com.cn
Expansion bolts can be used to secure heavy objects to walls or floors. Can handle vertical and horizontal loads. By tightening the bolt, the nut on the opposite end pulls into the shell, expanding it outward and wedging it inside the hole in the wall or floor.
Expansion Bolt,Expansion Bolts For Steel,Expansion Bolts For Concrete,Expansion Screws
Hebei W.M fastener manufacturing CO.,Ltd , https://www.wmfasteners.com